{"title":"Particulate Emission Monitor","description":"\u003cp align=\"left\" class=\"MsoNormal\"\u003eThe reason for measuring the AC component is that compared to the DC component the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the build-up of process dust on the sensing rod. The EMP6 remote sensing head totally filters out any 50Hz or 60Hz frequencies related to mains supply. The amplified signal is then sent via data cable to control unit for further processing and display.\u003c\/p\u003e\n\u003cp align=\"left\" class=\"MsoNormal\"\u003e  Please find more details from\u003c\/p\u003e","products":[{"product_id":"goyen-emp6-p2-45200-bbd6-broken-bag-detector","title":"GOYEN EMP6 P2-45200 BBD6-BROKEN BAG DETECTOR","description":"\u003cp\u003eGOYEN EMP6 P2-45200 BBD6-BROKEN BAG DETECTOR \u003c\/p\u003e\n\u003cdiv data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 20px; font-weight: 700; margin: 24px 0px 12px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-sae=\"\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" data-animation-nesting=\"\" role=\"heading\" aria-level=\"3\" class=\"otQkpb\"\u003e\n\u003cspan data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 20px; font-weight: 700; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-subtree=\"aimfl\"\u003e1. Overview of GOYEN EMP6 P2-45200 BBD6\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 12px 0px 16px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-processed=\"true\" data-complete=\"true\" data-hveid=\"CAAIBBAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"n6owBd awi2gc\"\u003eThe \u003cstrong data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 600; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eGOYEN EMP6 P2-45200 BBD6\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is a premium industrial \u003cstrong data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 600; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eBroken Bag Detector (BBD) and Particulate Emission Monitor\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e \u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 12px 0px 16px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-processed=\"true\" data-complete=\"true\" data-hveid=\"CAAIBRAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"n6owBd awi2gc\"\u003eInstead of a fluid control valve, this is a highly precise Electronic Sensor System designed to monitor dust emissions in the clean-air plenum or outlet stack of fabric filter baghouses. Its nomenclature represents a comprehensive system package:\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 12px 0px 16px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 0px 0px 12px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-sae=\"\" data-complete=\"true\" data-hveid=\"CAAIBhAA\" data-sfc-cb=\"\" data-sfc-root=\"ep\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 600; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eBBD6 \/ EMP6 (Control Unit)\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e: The central processing controller equipped with a 20-step LED bar-graph display to visualize live dust concentration levels and host the alarm relay logic.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 0px 0px 12px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-sae=\"\" data-complete=\"true\" data-hveid=\"CAAIBhAD\" data-sfc-cb=\"\" data-sfc-root=\"ep\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 16px; font-weight: 600; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eP2-45200 (Active Sensor Head)\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e: The physical sensing transmitter probe assembly that inserts into the ductwork. It features built-in advanced electronics to filter out 50Hz\/60Hz main-line industrial grid interference right at the measurement point.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 14px; font-weight: 400; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-sfc-inited=\"2\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003chr data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 14px; font-weight: 400; margin: 32px 0px; text-decoration: none; border-bottom: 0px rgb(128, 128, 128);\" data-sae=\"\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-pl=\"||[]\" data-sfc-root=\"c\" class=\"j3tEEe\"\u003e\n\u003cdiv data-copy-service-computed-style=\"font-family: Arial, sans-serif; font-size: 14px; font-weight: 400; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);\" data-sfc-inited=\"2\" data-processed=\"true\" data-complete=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e","brand":"GOYEN","offers":[{"title":"Default Title","offer_id":47684356964457,"sku":null,"price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0776\/2064\/1897\/files\/EMP6-P2-45200.jpg?v=1781149230"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0776\/2064\/1897\/collections\/goyen_emp6_81ae2821-4f56-4eb8-aaf7-e4ffe426a0e2.jpg?v=1781163603","url":"https:\/\/globefluid.com\/collections\/particulate-emission-monitor.oembed","provider":"GLOBEFLUID","version":"1.0","type":"link"}